Zone
Zone
INPUTS & OUTPUTS
VCC-X Controller Technical Guide
50
VCC-X Controller & RSMV Module Input/Output Maps
Input/Output Map
See Table 2 for the VCC-X Controller’s Input/Outputs, Table 3 for
the Refrigeration System Module for VFD Compressor’s Inputs/
Outputs, and Table 4 for the VCC-X EM1 Expansion Module’s
Inputs/Outputs.
VCC-X CONTROLLER
Analog Inputs
1 Space Temperature (AI1)
2 Space Slide Offset (AI2)
3 Supply Air Temperature (AI3)
4 Return Air Temperature (AI4)
5 Building Pressure (AI5)
6 Supply Air Temperature Reset (AI6)
7 Outside Air Temperature (AI7)
8 Static Pressure (Phone Jack)
Binary Inputs
1 Proof of Flow (BIN1)
2 Dirty Filter (BIN2)
3 Hood On/Off (BIN3)
4 Remote Forced Occupied (BIN4)
5 Remote Forced Cooling (BIN5)
6 Remote Forced Heating (BIN6)
7 Remote Forced Dehumidi cation (BIN7)
8 Emergency Shutdown (BIN8)
Analog Outputs (0-10 VDC)
1 Main Supply Fan VFD (AOUT1)
2 Economizer (Outdoor Air Damper) (AOUT2)
3
Modulating Heating (Hot Water, Steam, or SCR)
(AOUT3)
4
Exhaust Fan VFD / Building Pressure Control
Signal (AOUT4)
Binary Outputs (24 VAC)
1 Fan Relay (RLY1)
2 Con gurable Relay (RLY2)
3 Con gurable Relay (RLY3)
4 Con gurable Relay (RLY4)
5 Con gurable Relay (RLY5)
6 Con gurable Relay (RLY6)
7 Con gurable Relay (RLY7)
8 Con gurable Relay (RLY8)
Table 2: VCC-X Controller Inputs & Outputs
NOTE: The following E-BUS sensors and modules are avail-
able to connect to the VCC-X Controller via E-BUS ports or
E-BUS Expansion Modules:
1. E-BUS Digital Room Sensor - LCD Display - Temp Only or
Temp & Humidity
2. E-BUS Digital Room Sensor - No LCD Display - Temp &
Humidity
3. E-BUS Space and Return Air CO
2
Sensors
4. E-BUS connection to EBTRON, GreenTrol and Paragon
Air Flow Stations
5. E-BUS Outside Air Temperature & Humidity Sensor
Table 3: RSMV Inputs & Outputs
REFRIGERATION SYSTEM MODULE
FOR VFD COMPRESSORS
Analog Inputs
1 Suction Pressure Sensor (SP)
2 Head Pressure Sensor (HP)
3
Coil (Suction Line) Temperature Sensor 1
(TEMP1)
4
Coil (Suction Line) Temperature Sensor 2
(TEMP2)
Binary Inputs
1 Compressor Status 1 (BIN1)
2 Compressor Status 2 (BIN2)
Analog Outputs (0-10 VDC)
1 Modulating Compressor (AOUT1)
2 Condenser Fan Signal (AOUT2)
Stepper Motor Outputs
1 Expansion Valve 1 (EXV-1)
2 Expansion Valve 2 (EXV-2)
Binary Outputs (24 VAC)
1 Compressor 1 Enable Relay (R1)
2 Compressor 2 Enable Relay (R2)
3 Condenser Enable Relay (R3)
Table 2, cont.: VCC-X Controller Inputs & Outputs