GPC-XP Controller
Technical Guide
RELAY CONTACT
RATING IS 1 AMP
MAX @ 24 VAC
RS-485 COMMUNICATION LOOP. WIRE
“R” TO “R”, “T” TO “T” “SHLD” TO “SHLD”
RELAY 2
RELAY 6
RELAY 1
RELAY 5
RLY 1 =
VDC
OUTPUTS
AI1 =
+ 24 VDC
+ 5 VDC
GND
BI1 = AO1 =
AI2 = BI2 = AO2 =
AI3 = BI3 = AO3 =
AI4 = BI4 = AO4 =
AI5 = BI5 =
AI6 = BI6 =
AI7 = BI7 =
AI8 = BI8 =
RLY 2 =
RLY 5 =
RLY 3 =
RLY 6 =
RLY 4 =
RLY 7 =
RLY 8 =
RELAY 3
RELAY 7
RELAY 4
RELAY 8
COMMON
COMMON
USB
PORT
E-BUS
PORT
NOTES:
1.) ANALOG INPUT JUMPER SETTINGS MUST BE
SET FOR YOUR SPECIFIC INPUT DEVICE
REQUIREMENT.
2.) IT IS RECOMMENDED THAT YOU WRITE THE
DESCRIPTION OF THE INPUT, AND/OR
OUTPUTS YOU ARE CONNECTING TO THE
CONTROLLER IN THE BOXES PROVIDED ABOVE
USING A PERMANENT MARKER (SHARPIE ) FOR
FUTURE REFERENCE.
®
24 VAC POWER ONLY
WARNING! POLARITY MUST BE OBSERVED
OR THE CONTROLLER WILL BE DAMAGED
www.wattmaster.com
AI1
AI2
AI3
AI4
AI5
AI6
AI7
AI8
THERM
4-20mA
0-10V
0-5V
ANALOG
INPUT
JUMPERS
LED BLINK CODES
LED NAME
STATUS1
STATUS2
NORMAL OPERATION 0 1
SCHEDULE OVERRIDE 0 2
OE338-23-GPC-XP
GPC-XP CONTROLLER
WattMaster Label
#LB102095
Rev.: 1C
+ 24 VAC
GND
JUMPER 1
JUMPER 2
SETTING
ON
ON
USE ON-BOARD COMMLINK
OFF
OFF
USE EXTERNAL COMMLINK
www.wattmaster.com
Vista de pagina 0
1 2 3 4 5 6 ... 59 60

Indice de contenidos

Pagina 1 - Technical Guide

GPC-XP Controller Technical GuideRELAY CONTACTRATING IS 1 AMPMAX @ 24 VACRS-485 COMMUNICATION LOOP. WIRE“R” TO “R”, “T” TO “T” “SHLD” TO “SHLD”RELAY 2

Pagina 2 - Table of Contents

Section 3: GPC-XP Navigation & StatusGPC-XP Controller Technical Guide 10Selecting and Naming GPC-XP ControllersSelecting GPC-XP ControllersNOT

Pagina 3

GPC-XP Controller Technical Guide Section 3: GPC-XP Navigation & Status11GPC-XP Controller Status ScreenFigure 8: GPC-XP Control

Pagina 4 - Step-By-Step Guide

Section 4: Confi guring Analog InputsGPC-XP Controller Technical Guide 12Components and Navigation Analog InputsThe Analog Inputs Window is locat

Pagina 5 - Dimensions and Mounting

GPC-XP Controller Technical Guide Section 4: Confi guring Analog Inputs13Analog Input Confi guration Screen Confi guring Analog InputsLeft-click i

Pagina 6 - Installation & Wiring

Section 4: Confi guring Analog InputsGPC-XP Controller Technical Guide 14Sensor Reading, Scaling, and Override Duration Sensor Reading AppendixSelect

Pagina 7 - Communication Settings

GPC-XP Controller Technical Guide Section 4: Confi guring Analog Inputs15Reading Average, Broadcast, and Scaling Number of Readings to Averag

Pagina 8 - BAUD RATE SELECTION

Section 4: Confi guring Analog InputsGPC-XP Controller Technical Guide 16 Alarm Confi gurationHigh and Low Alarm Limits can be programmed if the job-s

Pagina 9 - Initialization

GPC-XP Controller Technical Guide Section 5: Confi guring Binary Inputs17Components and Navigation Binary InputsThe Binary Inputs Window is

Pagina 10 - Naming GPC-XP Controllers

Section 5: Confi guring Binary InputsGPC-XP Controller Technical Guide 18 Confi guring Binary InputsLeft-click on the “ON” or “OFF” button to the righ

Pagina 11

GPC-XP Controller Technical Guide Section 5: Confi guring Binary Inputs19Send Global Binary, Alarm Confi guration & Internal Schedule Send

Pagina 12 - Components and Navigation

Table of Contents GPC-XP Controller Technical Guide 2OVERVIEW ...

Pagina 13 - Confi guring Analog Inputs

Section 6: Confi guring RelaysGPC-XP Controller Technical Guide 20 RelaysThe Relays Window is located in the upper right of the GPC-XP Controller Stat

Pagina 14 - Override Duration

GPC-XP Controller Technical Guide Section 6: Confi guring Relays21Relay Confi guration Window Confi guring RelaysLeft-click on the “ON

Pagina 15 - Send Global Analog

Section 6: Confi guring RelaysGPC-XP Controller Technical Guide 22Main Control Method Window Main Control MethodThe Main Control Method Window (Fig

Pagina 16 - Override

GPC-XP Controller Technical Guide Section 6: Confi guring Relays23Main Control Method WindowFigure 37: Control Source Field ● Foll

Pagina 17

Section 6: Confi guring RelaysGPC-XP Controller Technical Guide 24Figure 38: Control Source SetpointsControl Source Setpoints Main Control Method Wind

Pagina 18 - Binary Input Type

GPC-XP Controller Technical Guide Section 6: Confi guring Relays25Figure 43: Controlling ScheduleControlling Schedule FieldYou can se

Pagina 19

Section 6: Confi guring RelaysGPC-XP Controller Technical Guide 26Logical AND Control Method & Logical OR Control Method Logical AND Control Me

Pagina 20

GPC-XP Controller Technical Guide Section 6: Confi guring Relays27Timing & Alarming & Relay Output Type Timing & Alarmin

Pagina 21 - Relay Confi guration Window

Section 7: Confi guring Analog OutputsGPC-XP Controller Technical Guide 28 Analog OutputsThe Analog Outputs Window is located in the lower right-hand

Pagina 22 - Main Control Method Window

GPC-XP Controller Technical Guide Section 7: Confi guring Analog Outputs29Confi guring Analog OutputsLeft-click in the data entry fi eld in the Ana

Pagina 23

GPC-XP Controller Technical Guide Overview3OverviewThe GPC-XP Controller ( OE338-23-GPC-XP) is use

Pagina 24

Section 7: Confi guring Analog OutputsGPC-XP Controller Technical Guide 30Control Type Floating Point ControlFloating Point Control works best on sl

Pagina 25

GPC-XP Controller Technical Guide Section 7: Confi guring Analog Outputs31 Control SourceThe Control Source Options are as follows (Figure 57 belo

Pagina 26 - Control Method

Section 7: Confi guring Analog OutputsGPC-XP Controller Technical Guide 32Outdoor Air Enable, Controlling Schedule, Enabling Relay Outdoor Air Enable

Pagina 27 - Lead/Lag Control

GPC-XP Controller Technical Guide Section 7: Confi guring Analog Outputs33Alternate Override and Override Alternate OverrideAn Alternate Override

Pagina 28

Section 8: Outdoor Status & AVC StatusGPC-XP Controller Technical Guide 34 AVC StatusThe AVC (Analog Value Comparison) Status Window is located i

Pagina 29 - Confi guring Analog Outputs

GPC-XP Controller Technical Guide Section 9: Setting Schedules35Schedules Window Components and Navigation Schedule Status WindowT

Pagina 30 - Control Type

Section 9: Setting SchedulesGPC-XP Controller Technical Guide 36Schedules WindowSetting SchedulesClick the <Schedule> button in the Schedules

Pagina 31 - Figure 57: Control Source

GPC-XP Controller Technical Guide Section 9: Setting Schedules37 Saving, Restoring & Copying Schedules Saving SchedulesTo sav

Pagina 32 - Output Voltage Limits

Section 9: Setting SchedulesGPC-XP Controller Technical Guide 38Click on the date to highlight it and tag it as a holiday. Days selected as holidays

Pagina 33 - Alternate Override

Section 10: Confi guring AlarmsGPC-XP Controller Technical Guide 39 Confi guring Alarms Alarm Notifi cationThe GPC-XP can generate alar

Pagina 34 - Outdoor Status

ZoneZoneOverviewGPC-XP Controller Technical Guide 4Step-By-Step Guide Step-By-Step GuideThis guide will lead you through each step in confi guring your

Pagina 35 - Schedule Status Window

Section 11: Miscellaneous SettingsGPC-XP Controller Technical Guide 40Miscellaneous Settings ScreenThe Miscellaneous Settings Screen includes setting

Pagina 36 - Schedules Window

GPC-XP Controller Technical Guide Section 11: Miscellaneous Settings41 Week Schedule BroadcastsThe Week Schedule Broadcasts Window (Figure 86

Pagina 37

Section 11: Miscellaneous SettingsGPC-XP Controller Technical Guide 42Rogue Sensor Limits & Reset & Outdoor Air BroadcastsFigure 89: Rogue S

Pagina 38

GPC-XP Controller Technical Guide Section 11: Miscellaneous Settings43 Trend Logging IntervalIn the Trend Logging Interval Window (Figure 93

Pagina 39 - Confi guring Alarms

Section 12: Saving and Restoring SetpointsGPC-XP Controller Technical Guide 44Saving and Copying Setpoints Saving GPC-XP SetpointsYou can save all s

Pagina 40 - Screen Components

GPC-XP Controller Technical Guide Section 13: Trend Logging & Printing45Trend Logging and Printing Trend Logging and PrintingBefore you s

Pagina 41 - AVC Inputs

Section 13: Trend Logging & PrintingGPC-XP Controller Technical Guide 46 Graphing and Printing Trend LogsTo print a log, fi rst select a printer

Pagina 42 - Outdoor Air Broadcasts

GPC-XP Controller Technical Guide Section 13: Trend Logging & Printing47Trend Log Select Unit and Printing Status ReportsFigure 109: Print

Pagina 43 - Reset Defaults

Appendix AGPC-XP Controller Technical Guide 48Global Analog & Global Binary Help ScreensFigure 110: Global Analog Help ScreenFigure 111: Globa

Pagina 44 - Saving and Copying Setpoints

GPC-XP Controller Technical Guide Appendix A49Figure 113: Formula Help ScreenFormula He

Pagina 45 - Trend Logging and Printing

GPC-XP Controller Technical Guide Section 1: GPC-XP Wiring & Setup5Dimensions and MountingPower SupplyThe GPC-XP Controller requires

Pagina 46

Appendix AGPC-XP Controller Technical Guide 50Status Report Example Status Report ExampleTo print a status report for the current day, from the GPC-XP

Pagina 47 - Printing Status Reports

GPC-XP Controller Technical Guide Appendix A51Figure 115: Status Report Preview Window

Pagina 48 - Appendix A

Appendix BGPC-XP Controller Technical Guide 52 USB Serial Converter and Serial Port Driver InstallationThe internal USB communication port of the GPC-

Pagina 49 - Formula Help Screen

GPC-XP Controller Technical Guide Appendix B53Changing the COM Port Number4. To assign

Pagina 50 - Status Report Example

IndexGPC-XP Controller Technical Guide 54A-B0 - 5vdc User Scaled...134 - 20mA User Scaled...1324 Hour Operation...37A

Pagina 51

GPC-XP Controller Technical Guide Index55CCalculation Interval...30C

Pagina 52 - USB Driver Installation

IndexGPC-XP Controller Technical Guide 56GGBD Average Reading...31,33GBD Inputs...34GBD Lowest Reading...31GBD Peak R

Pagina 53 - Changing the COM Port Number

GPC-XP Controller Technical Guide Index57OOA Dewpoint...31,33,34OA H

Pagina 54

IndexGPC-XP Controller Technical Guide 58SSaving GPC-XP Setpoints...44Saving Schedules...37Schedule Confi guration Window...

Pagina 55 - Disable Relay...27

GPC-XP Controller Technical Guide Index59V-WVVentilation Control...2

Pagina 56

Section 1: GPC-XP Wiring & SetupGPC-XP Controller Technical Guide 6Important Wiring ConsiderationsPlease read carefully and apply the following

Pagina 57

Form: WM-GPCXP-TGD-01E Printed in the USA May 2015All rights reserved. Copyright 2015WattMaster Contr

Pagina 58

GPC-XP Controller Technical Guide Section 1: GPC-XP Wiring & Setup7 Communication SettingsBefore Applying PowerIn order to have a troub

Pagina 59

ZoneZoneSection 1: GPC-XP Wiring & SetupGPC-XP Controller Technical Guide 8Controller Addressing and Baud RateThe GPC-XP Controller is equi

Pagina 60

GPC-XP Controller Technical Guide Section 2: Installing Prism 29 InitializationOn system power up, there is an approximately 30-se

Comentarios a estos manuales

Sin comentarios