RNE Modular Controller Field Technical Guide
OVERVIEW
11
Parts and Descriptions
PART NO. PART DESCRIPTION ILLUSTRATION PAGE NO.
OE415-02 IP Module Kit - Internet/LAN Connection
Used for Internet or Local Area Network communications with the control
system. Field installs by plugging into the CommLink IV circuit board and
provides an addressable Ethernet connection to the controls system from
any computer connected to your building’s LAN. It can also be confi gured to
allow access to the control system from the Internet through your LAN if your
Ethernet fi rewall is confi gured for this option.
Includes: IP Link module, 10 ft. long Ethernet cable, and installation instruc-
tions. Prism 2 computer front-end software must be installed on the remote
computer in order to dial-up and communicate with the controls system.
See the IP
Module
Technical
Guide
OE366 USB-Link 2 Kit
The USB-Link 2 is a pocket-sized communications interface used to connect
a laptop computer to your controls system for programming and monitoring
purposes, utilizing a modular cable to allow connection to the service port
connector on the controllers and a USB cable to connect to a laptop com-
puter.
Includes: USB-Link 2 for multiple or single loop systems, USB cable, modular
connection cable, two mini-DIN to terminal adapters, and Prism 2 software.
See the
USB-Link 2
Technical
Guide
OE364-22 MiniLink Polling Device
Control enclosure is for indoor use only. Used with all Orion controllers to
provide network communications, zone voting, alarming, and tenant logging
capabilities. A MiniLink Polling Device is required on each loop of a Net-
worked system. Includes: MiniLink Polling Device mounted in the EE000075-
01 control enclosure. Control Enclosure cover is shown removed in picture.
EPROM
U3
U5
RAM
CX2
1
U2
R1
C3
U4
CX3
CX4
YS101818P552
PROCESSORPBOARD
CX5
C1
U1
R2
CX1
CX6
WDOG
U6
PHILIPS
D1
P1
X1
C2
C4
0-10V
4-20mA
THERM
R27
R31
D4
GND
24VAC
TB1
D5
C11
U12
LED 2
POWER
V1
R25
R26
C7
CX15
CX13
PROC.
DRIVER
LOOP
DRIVER
LOCAL LOOP
GND
AIN 2
AIN 1
+5V
TB2
P4
OFF=0-5V
AIN2
AIN
1
0-10V
4-20mA
THERM
SHLD
T
TB3
R
U15
LD5
LD6
U13
C8
LED 1
RV1
R4
VREF
CX2
U11
YS101900PMINILINK
POLLING
DEVICE
REV. 1
OFF
1
2
4
8
16
32
CX14
NETWORK
DRIVER
RN3
SHLD
T
TB4
R
U14
NETWORK
LOOP
P5
ADD
P3
R24
LD4
C9
U10
RN2
SW1
R30
X2
R29
R28
C10
U6
CX6
CX1
U7
U1
X1
C3
C1
R3
CX7
See the
CommLink
IV Technical
Guide
OE365-15-
EBA
E-BUS Adapter Board
The E-BUS Adapter Board is used for connecting the EBTRON
®
, GreenTrol
TM
or Paragon Airfl ow Measurement Digital Transmitter to the VCB-X Control
System. The E-BUS Adapter Board connects to the VCB-X Controller with an
EBC E-BUS cable. Cable supplied separately.
See
Page 39.
OE508 Prism 2 Front-End Computer Software
Prism 2 provides standard, easy to understand status screens for each
type of RNE equipment installed. Prism software has provisions for custom
screens which allow fl oor plans, equipment photos, or user-defi ned summary
screens to be implemented to meet their own individual needs. All controlling
setpoints, trend logs, and alarm conditions are accessed in the Prism environ-
ment. Prism can be confi gured for direct on-site installation, remote modem
connection, or TCP/IP Internet connection to several installations.
See the
Prism 2
Technical
Guide
OE437-03 Communication Surge Protector Kit
Used to isolate power surges to the communications wiring caused by
lightning strikes for communications wiring loops that are routed outdoors or
between buildings. One kit is required at each point where the communica-
tions wiring leaves or enters a building.
Includes: Communication Bus Surge Protector, Base Module, and Mounting/
Wiring Instructions.
N/A