OE377-26-00060
(AAON Part No. V20780)
MODGAS-XWR Controller
Technical Guide
YS102530 REV 1
GAS VALVE 2
GAS VALVE 1
PO-IGN2
PO-IGN1
COMMON
RLY4
RLY3
RLY2
RLY1
WATTMASTER
CONTROLS
MADE IN USA
AUX BIN
HEAT EN
RESET IN
OPTIONS
SAT
GND
AUX AIN
GND
STATUS
ALARM
COMM
POWER
ANODE
ANODE
ANODE
M
ENTER
UP
DOWN
ALARM
MENU
OE377-26-00060
MODGAS-XWR
AAON No.: V20780
WattMaster No:
#SW000055
Rev.: 1A
E-BUS
CONNECT
I2C
CONNECT
+24 VAC
GND
CONTACT RATING
IS 1 AMP MAX
@ 24 VAC
HEAT 1
LOW SPEED
FAN
PROOF OF IGNITION 1
PROOF OF IGNITION 2
GAS VALVE 2
GAS VALVE 1
GAS VALVE
TERMINALS
HEAT 2
COMMON
RELAY OUTPUT
TERMINALS
INPUT TERMINALS (TYPE)
HEAT ENABLE (BI)
AUX. (BI)
GND
RESET INPUT (AI)
SAT INPUT (AI)
GND(AI)
GND
AUX. (AI)
www.aaon.com
Factory Packaged Controls
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Technical Guide

OE377-26-00060(AAON Part No. V20780)MODGAS-XWR Controller Technical GuideYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2PO-IGN1COMMONRLY4RLY3RLY2RLY1WATTM

Pagina 2 - TABLE OF CONTENTS

WIRING MODGAS-XWR Technical Guide 10Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2PO-IGN1COMMONRLY4RLY3RLY2RLY1WATTMASTERCON

Pagina 3 - General Information

MODGAS-XWR Technical Guide WIRING11Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE

Pagina 4

ZoneZoneINPUTS & OUTPUTS12 MODGAS-XWR Technical Guide Inputs and OutputsTable 1: MODGAS-XWR Controller Inputs & Outputs An

Pagina 5 - Stand-Alone Wiring

OPERATION MODES & STAGING CONFIGURATIONS13 MODGAS-XWR Technical Guide Operation Modes & Staging Con

Pagina 6

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 14Navigation KeysLCD Display Screen & Navigation KeysThe MODGAS-XWR Controller allows you to mak

Pagina 7

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS15Main Screens Map and MODGAS ScreensMain MODGAS ScreensRefer to the foll

Pagina 8

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 16Status ScreensStatus ScreensRefer to the following map when navigating through the Status Screens. Fr

Pagina 9

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS17Alarm ScreensRefer to the following map when viewing Alarm Screens. The

Pagina 10 - WIRING

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 18Force Valve & Confi guration ScreensForce Valve ScreensRefer to the following map when navigating

Pagina 11 - Communicating Wiring

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS19Confi guration & Diagnostic ScreensADDRESS1 TO 4TMPSCALEFAHRENHT CUR

Pagina 12 - Inputs and Outputs

TABLE OF CONTENTS MODGAS-XWR Technical Guide 2OVERVIEW & FEATURES ...

Pagina 13 - Operation Modes

TROUBLESHOOTING MODGAS-XWR Technical Guide 20LED DiagnosticsLED DiagnosticsThe MODGAS-XWR Controller is equipped with LEDs that can be used to veri

Pagina 14 - Navigation Keys

MODGAS-XWR Technical Guide TROUBLESHOOTING21Figure 10: MODGAS-XWR Controller LED Locations and DescriptionsYS1025

Pagina 15 - Protected Screens Map

TROUBLESHOOTING MODGAS-XWR Technical Guide 22Troubleshooting AlarmsMechanical Failure:• Check relay outputs on the MODGAS-XWR for 24 VAC output.•

Pagina 16 - Status Screens

MODGAS-XWR Technical Guide TROUBLESHOOTING23TroubleshootingOther Checks0-3.3V (SAT OPTIONS Jumper Setting 1) &

Pagina 17 - Alarm & Setpoint Screens

TROUBLESHOOTING MODGAS-XWR Technical Guide 24Table 6, cont.: 0-5V Temperature Sensor - Voltage & Resistance for Type III SensorsThermistor Sen

Pagina 18

MODGAS-XWR Technical Guide APPENDIX A25Supply Air Temperature Sensor InstallationMounting the Supply

Pagina 19 - Diagnostic Screens

APPENDIX A MODGAS-XWR Technical Guide 26SAT Sensor Wiring Guide & Jumper SettingsSAT Options Jumper SettingsRefer to Tables 8 & 9 to determin

Pagina 20 - LED Diagnostics

MODGAS-XWR Technical Guide APPENDIX B27MODGAS-XWR Replacement of MODGAS IIReplacing the MODGAS II wit

Pagina 21 - Troubleshooting

2425 So. Yukon Ave • Tulsa, OK 74107-2728Ph: (918) 583-2266 • Fax: (918) 583-6094AAON® Manual Part No. V22330WattMaster Manual Form No: AA-MODGASXWR-T

Pagina 22 - Troubleshooting Alarms

MODGAS-XWR Technical Guide OVERVIEW3General InformationYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2

Pagina 23

WIRING MODGAS-XWR Technical Guide 4Important Wiring ConsiderationsImportant Wiring ConsiderationsPlease read carefully and apply the following i

Pagina 24

MODGAS-XWR Technical Guide WIRING5Fan EnableLow Speed FanSeeFor SAT OPTIONS Jumper SettingsOn

Pagina 25

WIRING MODGAS-XWR Technical Guide 6Single Modulating Valve & 1 Fixed Heat Stage - Stand-AloneFigure 3: Single Modulating Valve & 1 Fixe

Pagina 26 - APPENDIX A

MODGAS-XWR Technical Guide WIRING7Fan EnableLow Speed FanSeeFor SAT OPTIONS Jumper SettingsOn

Pagina 27 - MODGAS-XWR

WIRING MODGAS-XWR Technical Guide 812-Relay E-BUS Expansion Module - Stand Alone One Modulating Valve with 1 Fixed Stage or Two Modulating Valve

Pagina 28 - Manual Part No. V22330

MODGAS-XWR Technical Guide WIRING9Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE 1